6/7/12 05043G © Inovonics, 2012 - www.inovonics.com
EN1215WEOL EchoStream® Universal
Transmitter with Wall Tamper
Installation Instructions
1 Overview
The Inovonics EN1215WEOL wide gap universal transmitter with an
included wall tamper switch has a built-in magnetic reed switch on the
side, with a magnet that supports a 5/8" inch gap. The magnetic reed
switch can be used with both ferrous and non-ferrous material. A 2.2K
ohm end of line resistor is included with the EN1215WEOL, and is
required for operation.
The EN1215WEOL includes a back tamper switch. The tamper condition
must be defined within the control panel as a trouble condion when the
system is disarmed, and as an alarm condition when the system is armed.
Note: For UL installations, refer to the EN4216MR Installation and
Operation Manual, the EN4232MR Installation and Operation Manual, or
the EN7285 Installation Instructions. The switch contact must also be
located in the same room as the EN1215WEOL, and the EN1215WEOL
must be installed in accordance with UL 681 and ULc S302.
Note: The cable length from the switch contact must not to exceed 10
feet.
Caution: The EN1215WEOL contains both a wired input and an input
activated by a reed switch and magnet. The reed switch and magnet
MUST be used unless the application (control panel) specifically supports
both inputs as separate devices. Use of the wired input is optional.
1.1 Inovonics Wireless Contact Information
If you have any problems with this procedure, contact Inovonics technical
services:
E-mail: support@inovonics.com
Phone: (800) 782-2709
1.2 EN1215WEOL External Components
Figure 1 EN1215WEOL external components
1.3 EN1215WEOL Internal Components
Figure 2 EN1215WEOL internal components
1.4 What’s In The Carton
Wall mount screws
Wall mount anchors
Selection jumpers
3.0V lithium battery
Housing closure screw
Magnet
2.2K ohm end of line resistor
2 Installation and Startup
2.1 Installation Notes
These products are designed to be installed and maintained by
professional security technicians.
Products are intended for indoor use.
Manually test all products weekly.
2.2 Initial Setup
Battery Installation
1. Insert a small screwdriver to depress the housing release tab on the
bottom of the transmitter; pry the housing apart.
Figure 3 Open the EN1215WEOL Housing
2. Install the new battery.
3. Press the Reset button to initialize the transmitter.
4. Test the transmitter and ensure appropriate response.
Select the Frequency Band
EchoStream products are able to use a range of radio frequencies, and
must be configured for your geographic area. This product ships with a
default frequency range of 902-928 MHz for use in North America. If you
are using the product in North America, skip to step 7; if you are using the
product in Australia or New Zealand, you will need to configure the
transmitter.
5. Place a selection jumper on the appropriate frequency band selection
pins.
Place the jumper on the right two pins, marked NZ, to set the
frequency range to 921-928 MHz for New Zealand.
Place the jumper on the left two pins, marked AU, to set the
frequency range to 915-928 MHz for Australia.
Note: Only devices set for use in North America are configured for UL
installations.
6. Press the Reset button to complete configuration.
Caution: When pressing the Reset button, make sure you don’t also
touch the frequency band selection pins. Touching the frequency band
selection pins while pressing the Reset button can inadvertently set the
EN1215WEOL to the wrong frequency band.
Select Input Type and Wire Resistor
The N/O-N/C selection pins allow the choice of a normally open or
normally closed state for the contact circuit wired to the input terminal.
The transmitter is shipped set for normally open, with a selection jumper
on the N/O selections pins.
Set for normally open operation:
7. Place a selection jumper on the selection pins to select normally
open.
8. Use 22 AWG wire to wire the 2.2K ohm resistor in parallel with the N/0
contact per Figure 4. The distance from the external contact to the
EN1215WEOL must not exceed 10 feet (3 meters).
9. Press the Reset button to complete configuration.
Figure 4 Wired for N/O operation
Set for normally closed operation:
10. Remove the selection jumper from the selection pins.
11. Use 22 AWG wire to wire the 2.2K ohm resistor in series with the N/C
contact per Figure 5. The distance from the external contact to the
EN1215WEOL must not exceed 10 feet (3 meters).
12. Press the Reset button.
Figure 5 Wired for N/C operation
A Housing closure screw hole B Wall tamper switch
A
B
A Housing tamper button B N/O - N/C jumper
C Input terminal D Reset button
E Wall-mount screw holes F Housing closure screw hole
G Reed switch H Frequency band selection pins
A
B
C
D
E
E
F
G
H
Vue de la page 0
1 2

Résumé du contenu

Page 1 - Transmitter with Wall Tamper

6/7/12 05043G © Inovonics, 2012 - www.inovonics.comEN1215WEOL EchoStream® Universal Transmitter with Wall TamperInstallation Instructions1 OverviewThe

Page 2 - 3.1 Battery Replacement

6/7/12 05043G © Inovonics, 2012 - www.inovonics.comRegister the EN1215WEOLTransmitters must be registered with the system in order to be monitored and

Commentaires sur ces manuels

Pas de commentaire